Home

Mazdamanuals.com

SIMULATION TABLE [PCM (SKYACTIV-D)]

SIMULATION TABLE [PCM (SKYACTIV-D)]


 id0102t5350100

—: Not applicable

Simulation item

Unit/Condition

Definition

Operation condition

Engine condition

Other condition

A/C_REQ
No (False)/Yes (True)
•  Select No (False)/Yes (True) to drives/stops the A/C condition.
•  Idle
A/C_RLY
FALSE/TRUE
•  Select FALSE/TRUE to drives/stops the A/C relay.
•  Ignition is switched ON (engine off)
AIRSHUT_POS_COMD
%
•  Changes % to forcibly open/close the active air shutter.
•  Ignition is switched ON (engine off)
•  Idle
•  Racing (not idle)
COOL_VLV_DSD
° (deg)
•  Changes ° (deg) and forcibly drives/stops the coolant control valve.
•  Ignition is switched ON (engine off)
•  Idle
•  Racing (not idle)
Note
•  Override drive parameter input range: 10—215°
E_WATER_PUMP
% Duty Cycle
•  Changes % and forcibly drives/stops the electric water pump.
•  Ignition is switched ON (engine off)
•  Idle
EX_SHUT_VLV_DSD
%
•  Changes % and forcibly drives/stops the exhaust shutter valve.
•  Ignition is switched ON (engine off)
•  Idle
FAN
%
•  Changes % and forcibly drives/stops the fan control module.
•  Ignition is switched ON (engine off)
•  Idle
Note
•  Override drive parameter input range: 0—100%
HI_PRES_EGR_VLV_DSD
%
•  Changes % and forcibly drives/stops the HP-EGR control valve.
•  Ignition is switched ON (engine off)
•  Idle
INJ
Fuel Injector 1 requested closed/
Fuel Injector 2 requested closed/
Fuel Injector 3 requested closed/
Fuel Injector 4 requested closed/
All Fuel Injectors requested closed
•  Forcibly stops the fuel injectors while the engine is idling.
•  Idle
Warning
•  Do not use the simulation function while the vehicle is being driven. Stopping the fuel ejection causes the engine to stall which may cause the brakes to not function.
INTAKE_SHUT_VLV_ANG_COMD
° (deg)
•  Changes ° (deg) and forcibly drives/stops the intake shutter valve.
•  Ignition is switched ON (engine off)
•  Idle
LO_PRES_EGR_VLV_DSD
%
•  Changes % and forcibly drives/stops the LP-EGR control valve.
•  Ignition is switched ON (engine off)
•  Idle
RPM_DSD
Rpm
•  Changes value (Rpm) to forcibly vary the engine speed.
•  Idle
•  Racing (not idle)
Note
•  Override drive parameter input range: 1,000—2,000 Rpm
TURBO_POS_DSD
%
•  Changes % and forcibly drives/stops the turbocharger actuator.
•  Idle