Home

Mazdamanuals.com

COOLING FAN MOTOR INSPECTION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (E))]

COOLING FAN MOTOR INSPECTION [SKYACTIV-G (WITH CYLINDER DEACTIVATION (E))]


 id0112u3801800


Cooling fan control system Inspection

1.  Connect the M-MDS to the DLC-2.

2.  Perform the KOEO or KOER self-test using the M-MDS and verify that none of the following DTCs is detected. (See DTC INSPECTION.)

•  P0117:00
•  P0118:00
•  P0480:00
•  P0481:00
―  If any of the following DTCs can be verified, perform the applicable DTC inspection. (See DTC P0117:00 [PCM (SKYACTIV-G)].) (See DTC P0118:00 [PCM (SKYACTIV-G)].) (See DTC P0480:00 [PCM (SKYACTIV-G)].) (See DTC P0481:00 [PCM (SKYACTIV-G)].)

3.  Verify that the engine coolant temperature is less than 97°C {206°F}, and then start the engine and idle it.

4.  Verify that the cooling fan does not operate when the A/C switch is turned off.

•  If it is operating, perform the following inspections.

Inspection items
•  Cooling fan relay No.1 (stuck closed)
•  Cooling fan relay No.2 (stuck closed)
•  Wiring harness between cooling fan relay No.1 and cooling fan motor (short to power supply)
•  Wiring harness between cooling fan relay No.2 and cooling fan motor (short to power supply)
•  A/C pressure sensor
•  Climate control unit
•  CAN communication (PID: AC_REQ constantly ON)

5.  Verify that the cooling fan operates at a low speed when the L_SPD_FAN is turned from OFF to ON using the M-MDS simulation function.

•  If the operation cannot be verified, perform the following inspections.

Cooling fan status

Inspection items

OFF
•  Cooling fan relay No.1 (stuck open)
•  Cooling fan motor (internal open circuit)
•  Wiring harnesses between battery and cooling fan relay No.1, and cooling fan relay No.1 and cooling fan motor (fuse blown due to open circuit and short to ground)
•  Wiring harness between cooling fan motor and ground (open circuit and poor ground)

6.  Verify that the cooling fan operates at a high speed when the H_SPD_FAN is turned from OFF to ON using the M-MDS simulation function.

•  If the operation cannot be verified, perform the following inspections.

Cooling fan status

Inspection items

OFF
•  Cooling fan relay No.2 (stuck open)
•  Cooling fan motor (internal open circuit)
•  Wiring harnesses between battery and cooling fan relay No.2, and cooling fan relay No.2 and cooling fan motor (fuse blown due to open circuit and short to ground)
•  Wiring harness between cooling fan motor and ground (open circuit and poor ground)


Part Inspection

1.  Verify that the battery is fully charged. (See BATTERY INSPECTION [(E)].)

2.  Disconnect the cooling fan motor connector (3 terminals).

3.  Install a tester and battery to the cooling fan motor connector (3 terminals) as shown in the figure.

am3zzw00034769

4.  Verify that each cooling fan motor operates smoothly at the standard current.

•  If there is any malfunction, replace the applicable part.
Cooling fan motor standard current
World manufacturer identification except "3MV": 8.3—10.1 A [12 V]
World manufacturer identification "3MV": Approx. 11.6 A [12 V]