PID/DATA MONITOR TABLE [DASH-ELECTRICAL SUPPLY UNIT (E)]
id0702k80114ka
PID |
Unit/Operation |
Data contents |
Module control terminal |
---|---|---|---|
AIR_MIX_L
|
—
|
Displays the target actuator opening angle of the air mix actuator (LH).
|
2B
|
AIR_MIX_MODE_L
|
Stopped/AirMix LH Actuator Max Cold Position/AirMix LH Actuator Max Hot Position/AirMix LH Actuator Half Position
|
• Stopped: Air mix actuator (LH) is stopped
• AirMix LH Actuator Max Cold Position: Air mix actuator (LH) is operating so that air mix door position is at MAX COLD control
• AirMix LH Actuator Max Hot Position: Air mix actuator (LH) is operating so that air mix door position is at MAX HOT control
• AirMix LH Actuator Half Position: Air mix actuator (LH) is operating so that air mix door position is at middle position of MAX COLD control and MAX HOT control
|
2B
|
AIR_MIX_MODE_R
|
Stopped/AirMix RH Actuator Max Cold Position/AirMix RH Actuator Max Hot Position/AirMix RH Actuator Half Position
|
• Stopped: Air mix actuator (RH) is stopped
• AirMix RH Actuator Max Cold Position: Air mix actuator (RH) is operating so that air mix door position is at MAX COLD control
• AirMix RH Actuator Max Hot Position: Air mix actuator (RH) is operating so that air mix door position is at MAX HOT control
• AirMix RH Actuator Half Position: Air mix actuator (RH) is operating so that air mix door position is at middle position of MAX COLD control and MAX HOT control
|
2B
|
AIR_MIX_POS_L
|
—
|
Displays the actuator opening angle (feedback value) of the air mix actuator (LH).
|
2B
|
AIR_MIX_POS_R
|
—
|
Displays the actuator opening angle (feedback value) of the air mix actuator (RH).
|
2B
|
AIR_MIX_R
|
—
|
Displays the target actuator opening angle of the air mix actuator (RH).
|
2B
|
AMB_TEMP
|
°C, °F
|
Displays the ambient temperature detected by the ambient temperature sensor.
|
—
|
AMB_TEMP_INTERNAL
|
°C, °F
|
Displays the cabin temperature detected by the passenger compartment temperature sensor.
|
—
|
BLOWER_MOTOR_RLY
|
OFF/ON
|
• OFF: Blower relay is off
• ON: Blower relay is on
|
—
|
CRANKING_STAT
|
—
|
Displays during engine cranking or other than engine cranking.
|
—
|
ECT
|
°C, °F
|
Displays the engine coolant temperature detected by the ECT sensor.
|
—
|
EVA_TEMP
|
°C, °F
|
Displays the evaporator temperature detected by the evaporator temperature sensor.
|
2E
|
FOOT_LAMP
|
OFF/ON
|
|
1A
|
HEAT_CORE_TEMP
|
°C, °F
|
Heater core temperature is displayed.
|
—
|
ILLMI_POWER
|
—
|
Displays the illumination power supply condition.
|
—
|
ILLMI_STAT
|
OFF/ON
|
|
—
|
INTAKE_ACTAT
|
—
|
Displays the target actuator opening angle of the air intake actuator.
|
2B
|
INTAKE_ACTAT_MODE
|
Stopped/Intake Actuator Fresh Position/Intake Actuator Recirculation Position/Intake Actuator 25% Rec Position/Intake Actuator 50% Rec Position/Intake Actuator 75% Rec Position
|
• Stopped: Air intake actuator is stopped
• Intake Actuator Fresh Position: Intake actuator is operating so that intake door position is at FRESH 100%
• Intake Actuator Recirculation Position: Intake actuator is operating so that intake door position is at REC 100%
• Intake Actuator 25% Rec Position: Intake actuator is operating so that intake door position is at REC 25%/FRESH 75%
• Intake Actuator 50% Rec Position: Intake actuator is operating so that intake door position is at REC 50%/FRESH 50%
• Intake Actuator 75% Rec Position: Intake actuator is operating so that intake door position is at REC 75%/FRESH 25%
|
2B
|
INTAKE_ACTAT_POS
|
—
|
Displays the actuator opening angle (feedback value) of the air intake actuator.
|
2B
|
LIFT_DOWN_SW
|
Off/On
|
• Off: Lift switch is not in down
• On: Lift switch is in down
|
3J
|
LIFT_UP_SW
|
Off/On
|
• Off: Lift switch is not in up
• On: Lift switch is in up
|
3J
|
MEMORY_SEAT_LIFT
|
Stop/Moving Upward/Moving Downward
|
• Stop: Lift motor is stopped and front seat height is not adjusted upward and downward
• Moving Upward: Lift motor adjusts front seat height upward
• Moving Downward: Lift motor adjusts front seat height downward
|
3J
|
MEMORY_SEAT_RECLINE
|
Stop/Moving Forward/Moving Backward
|
• Stop: Recliner motor is stopped and angle of front seat back is not adjusted forward and rearward
• Moving Forward: Recliner motor adjusts angle of front seat back forward
• Moving Backward: Recliner motor adjusts angle of front seat back rearward
|
3J
|
MEMORY_SEAT_SLIDE
|
Stop/Moving Forward/Moving Backward
|
• Stop: Slide motor is stopped and front and back positions of front seat are not adjusted forward and rearward
• Moving Forward: Slide motor adjusts front and back positions of front seat forward
• Moving Backward: Slide motor adjusts front and back positions of front seat rearward
|
3J
|
MEMORY_SEAT_TILT
|
Stop/Moving Upward/Moving Downward
|
• Stop: Tilt motor is stopped and height of front seat cushion front side is not adjusted upward and downward
• Moving Upward: Tilt motor adjusts height of front seat cushion front side upward
• Moving Downward: Tilt motor adjusts height of front seat cushion front side downward
|
3J
|
MODE_ACTAT
|
—
|
Displays the target actuator opening angle of the airflow mode actuator.
|
2B
|
MODE_ACTAT_MODE
|
Stopped/Mode Actuator Vent Position/Mode Actuator Bi-Level Position/Mode Actuator Heat Position/Mode Actuator Def-Heat Position/Mode Actuator Defroster Position
|
• Stopped: Airflow mode actuator is stopped
• Mode Actuator Vent Position: Airflow mode actuator is operating so that mode door position is at VENT
• Mode Actuator Bi-Level Position: Airflow mode actuator is operating so that mode door position is at Bi-Level
• Mode Actuator Heat Position: Airflow mode actuator is operating so that mode door position is at HEAT
• Mode Actuator Def-Heat Position: Airflow mode actuator is operating so that mode door position is at DEF/HEAT
• Mode Actuator Defroster Position: Airflow mode actuator is operating so that mode door position is at DEFROSTER
|
2B
|
MODE_ACTAT_POS
|
—
|
Displays the actuator opening angle (feedback value) of the airflow mode actuator.
|
2B
|
POWER_SEAT_MOTOR_VOLT
|
V
|
Displays the power supply voltage (+B_PS) to the position memory control module
|
3J
|
POWER_STAT
|
—
|
Displays the ignition switch condition.
|
—
|
R_VENT_ACTAT
|
—
|
Displays the target actuator opening angle of the rear vent actuator.
|
2A
|
R_VENT_ACTAT_MODE
|
Stopped/Rear Vent Actuator Vent Position/Rear Vent Actuator Heat Position/Rear Vent Actuator Defroster Position
|
• Stopped: Rear vent actuator is stopped
• Rear Vent Actuator Vent Position: Rear vent actuator is operating so that rear vent door position is at VENT
• Rear Vent Actuator Heat Position: Rear vent actuator is operating so that rear vent door position is at HEAT
• Rear Vent Actuator Defroster Position: Rear vent actuator is operating so that rear vent door position is at DEFROSTER
|
2A
|
R_VENT_ACTAT_POS
|
—
|
Displays the actuator opening angle (feedback value) of the rear vent actuator.
|
2A
|
RECLINE_BACK_SW
|
Off/On
|
• Off: Recliner switch is not in backward
• On: Recliner switch is in backward
|
3J
|
RECLINE_FWD_SW
|
Off/On
|
• Off: Recliner switch is not in forward
• On: Recliner switch is in forward
|
3J
|
ROOM_FUSE_STAT
|
—
|
Displays the F27 25 A fuse condition.
|
—
|
S_BELT_STAT
|
Not Buckled/Buckled
|
• Not Buckled: Driver-side front seat belt not fastened (Driver-side buckle switch on)
• Buckled: Driver-side front seat belt fastened (Driver-side buckle switch off)
|
3H
|
SEAT_HEAT_VOLT_F
|
V
|
Displays the power supply voltage (+B_SH1, +B_SH2) to the seat warmer control unit.
|
3J
|
SEAT_UNIT_VOLT
|
V
|
Displays the power supply voltage (IG1) to the position memory control module/seat warmer control unit.
|
3J
|
SLIDE_BACK_SW
|
Off/On
|
• Off: Slide switch is not in backward
• On: Slide switch is in backward
|
3J
|
SLIDE_FWD_SW
|
Off/On
|
• Off: Slide switch is not in forward
• On: Slide switch is in forward
|
3J
|
SOLAR_SEN_L
|
W/m2
|
Displays the sunlight intensity on the left side of the windshield detected by the solar radiation sensor.
|
—
|
SOLAR_SEN_R
|
W/m2
|
Displays the sunlight intensity on the right side of the windshield detected by the solar radiation sensor.
|
—
|
STOP_START_STAT
|
Stop Available/Stop Not Available
|
• Stop Available: i-stop control enabled
• Stop Not Available: i-stop control disabled
|
—
|
TILT_DOWN_SW
|
Off/On
|
• Off: Tilt switch is not in down
• On: Tilt switch is in down
|
3J
|
TILT_UP_SW
|
Off/On
|
• Off: Tilt switch is not in up
• On: Tilt switch is in up
|
3J
|
VPWR
|