SIMULATION TABLE [DASH-ELECTRICAL SUPPLY UNIT (E)]
id0702k80115ka
Simulation item |
Unit/Operation |
Data contents |
Output part name |
---|---|---|---|
AIR_MIX_L
|
—
|
Sets the air mix actuator (LH) to the desired position.
|
Air mix actuator (LH)
|
AIR_MIX_MODE_L
|
Stopped/AirMix LH Actuator Max Cold Position/AirMix LH Actuator Max Hot Position/AirMix LH Actuator Half Position
|
• Stopped: Stops air mix actuator (LH)
• AirMix LH Actuator Max Cold Position: Operates air mix actuator (LH) until air mix door switches to MAX COLD position
• AirMix LH Actuator Max Hot Position: Operates air mix actuator (LH) until air mix door switches to MAX HOT position
• AirMix LH Actuator Half Position: Operates air mix actuator (LH) until air mix door switches to middle position between MAX COLD and MAX HOT positions
|
Air mix actuator (LH)
|
AIR_MIX_MODE_R
|
Stopped/AirMix RH Actuator Max Cold Position/AirMix RH Actuator Max Hot Position/AirMix RH Actuator Half Position
|
• Stopped: Stops air mix actuator (RH)
• AirMix RH Actuator Max Cold Position: Operates air mix actuator (RH) until air mix door switches to MAX COLD position
• AirMix RH Actuator Max Hot Position: Operates air mix actuator (RH) until air mix door switches to MAX HOT position
• AirMix RH Actuator Half Position: Operates air mix actuator (RH) until air mix door switches to middle position between MAX COLD and MAX HOT positions
|
Air mix actuator (RH)
|
AIR_MIX_R
|
—
|
Sets the air mix actuator (RH) to the desired position.
|
Air mix actuator (RH)
|
INTAKE_ACTAT
|
—
|
Sets the airair intake actuator to the desired position.
|
Air intake actuator
|
INTAKE_ACTAT_MODE
|
Stopped/Intake Actuator Fresh Position/Intake Actuator Recirculation Position/Intake Actuator 25% Rec Position/Intake Actuator 50% Rec Position/Intake Actuator 75% Rec Position
|
• Stopped: Stops air intake actuator
• Intake Actuator Fresh Position: Operates air intake actuator until air intake door switches to FRESH position
• Intake Actuator Recirculation Position: Operates air intake actuator until air intake door switches to REC position
• Intake Actuator 25% Rec Position: Operates air intake actuator until air intake door switches to position of REC 25%/FRESH 75%
• Intake Actuator 50% Rec Position: Operates air intake actuator until air intake door switches to position of REC 50%/FRESH 50%
• Intake Actuator 75% Rec Position: Operates air intake actuator until air intake door switches to position of REC 75%/FRESH 25%
|
Air intake actuator
|
MODE_ACTAT
|
—
|
Sets the airflow mode actuator to the desired position.
|
Airflow mode actuator
|
MODE_ACTAT_MODE
|
Stopped/Mode Actuator Vent Position/Mode Actuator Bi-Level Position/Mode Actuator Heat Position/Mode Actuator Def-Heat Position/Mode Actuator Defroster Position
|
• Stopped: Stops airflow mode actuator
• Mode Actuator Vent Position: Operates airflow mode actuator until mode door switches to VENT position
• Mode Actuator Bi-Level Position: Operates airflow mode actuator until mode door switches to Bi-Level position
• Mode Actuator Heat Position: Operates airflow mode actuator until mode door switches to HEAT position
• Mode Actuator Def-Heat Position: Operates airflow mode actuator until mode door switches to DEF/HEAT position
• Mode Actuator Defroster Position: Operates airflow mode actuator until mode door switches to DEFROSTER position
|
Airflow mode actuator
|
R_VENT_ACTAT
|
—
|
Sets the rear vent actuator to the desired position.
|
Rear vent actuator
|
R_VENT_ACTAT_MODE
|
Stopped/Rear Vent Actuator Vent Position/Rear Vent Actuator Heat Position/Rear Vent Actuator Defroster Position
|
• Stopped: Stops rear vent actuator
• Rear Vent Actuator Vent Position: Operates rear vent actuator until rear vent door switches to VENT position
• Rear Vent Actuator Heat Position: Operates rear vent actuator until rear vent door switches to HEAT position
• Rear Vent Actuator Defroster Position: Operates rear vent actuator until rear vent door switches to DEFROSTER position
|
Rear vent actuator
|