Home

Mazdamanuals.com

PID/DATA MONITOR TABLE [INTEGRATED STARTER GENERATOR (ISG)]

PID/DATA MONITOR TABLE [INTEGRATED STARTER GENERATOR (ISG)]


id140202100100

—: Not applicable

PID/data monitor item

Unit/Operation

Data contents

Integrated starter generator (ISG) terminal

ALT_MODE
—
•  Displays the integrated starter generator (ISG) power generation mode.
—
BATT_TERMINAL_CUR_EST
A
•  Displays the estimated current input to integrated starter generator (ISG) terminal 2A.
—
BATT_TERMINAL_VOLT
V
•  Displays the voltage input to integrated starter generator (ISG) terminal 2A.
2A
BATT_TERMINAL_VOLT_A/D
V
•  Displays the terminal 2A voltage supplied to the input voltage converter in the integrated starter generator (ISG).
—
BATT_TERMINAL_VOLT_GD
V
•  Displays the terminal 2A voltage supplied to the drive circuit in the integrated starter generator (ISG).
—
BATT_TERMINAL_VOLT_REQ
V
•  Displays the target value of the terminal 2A voltage input from the PCM.
—
B-ISG_RPM
r/min
•  Displays the rotor rotation speed.
—
CTRL_MODE
Standby / Torque Control / Voltage Control / System Waiting / System Stopping / System Wakeup / Braking
•  Displays the control status of the integrated starter generator (ISG).
―  Standby: During control standby
―  Torque Control: During power generation torque/drive torque control
―  Voltage Control: During voltage control
―  System Waiting: Activation of Mazda M Hybrid on standby
―  System Stopping: Ends activation of integrated starter generator (ISG)
―  System Wakeup: Starts activation of integrated starter generator (ISG)
―  Braking: During braking torque control
—
CTRL_MODE_REQ
Standby / Torque Control / Voltage Control / System Waiting / System Stopping / System Wakeup / Braking
•  Displays the control request signal of the integrated starter generator (ISG) input from the PCM.
―  Standby: During control standby
―  Torque Control: During power generation torque/drive torque control
―  Voltage Control: During voltage control
―  System Waiting: Activation of Mazda M Hybrid on standby
―  System Stopping: Ends activation of integrated starter generator (ISG)
―  System Wakeup: Starts activation of integrated starter generator (ISG)
―  Braking: During braking torque control
—
CTRL_TEMP
°C, °F
•  Displays the temperature detected by the control board temperature sensor in the integrated starter generator (ISG).
—
CTRL_TEMP_A/D
V
•  Displays the voltage conversion value for the control board temperature sensor temperature in the integrated starter generator (ISG) supplied to the input voltage converter in the integrated starter generator (ISG).
—
FIELD_COIL_TEMP_EST
—
•  Displays the field coil temperature (estimated) of the integrated starter generator (ISG).
—
FIELD_CUR
A
•  Displays the field coil current of the integrated starter generator (ISG).
—
FIELD_CUR_A/D
V
•  Displays the value of the field coil current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
FIELD_CUR_OFFSET_A/D
V
•  Displays the measurement difference error value of the field coil current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
FIELD_DUTY
%
•  Displays the field coil control duty value.
—
IG_CYCLE_COUNT
times
•  Displays the number of times power is supplied from the IG1 relay.
—
IG_SIG
—
SKYACTIV-G
•  Displays the power supply status from the electric variable valve timing relay.
SKYACTIV-X
•  Displays the power supply status from the exhaust electrical variable valve timing relay.
1B
IG_SIG_CAN
—
•  Displays the power supply status from the IG1 relay input via CAN communication.
—
MOSFET_TEMP
°C, °F
•  Displays the 6-phase FET temperature in the integrated starter generator (ISG).
—
MPU_TEMP
°C, °F
•  Displays the microcomputer temperature in the integrated starter generator (ISG).
—
TRQ_EST
N·m
•  Displays the output torque request value input from the PCM.
—
TRQ_RATE_LIM_DECREASE
N·m/s
•  Displays the speed at which the power generation torque decreases.
—
TRQ_RATE_LIM_INCREASE
N·m/s
•  Displays the speed at which the power generation torque increases.
—
U_PHASE_CUR_A/D
V
•  Displays the value of the U-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
U_PHASE_TEMP_A/D
V
•  Displays the voltage of the U-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
UNDER_VOLT_REQ
—
•  Displays the terminal 2A low voltage error signal of the integrated starter generator (ISG) input via CAN communication.
—
V_PHASE_CUR_A/D
V
•  Displays the value of the V-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
V_PHASE_TEMP_A/D
V
•  Displays the voltage of the V-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
VPWR
V
•  Displays the integrated starter generator (ISG) power supply voltage.
—
W_PHASE_CUR_A/D
V
•  Displays the value of the W-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
W_PHASE_TEMP_A/D
V
•  Displays the voltage of the W-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
X_PHASE_CUR_A/D
V
•  Displays the value of the X-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
X_PHASE_TEMP_A/D
V
•  Displays the voltage of the X-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
Y_PHASE_CUR_A/D
V
•  Displays the value of the Y-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
Y_PHASE_TEMP_A/D
V
•  Displays the voltage of the Y-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
Z_PHASE_CUR_A/D
V
•  Displays the value of the Z-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
—
Z_PHASE_TEMP_A/D
V
•  Displays the voltage of the Z-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
—