ALT_MODE
|
—
|
• Displays the integrated starter generator (ISG) power generation mode.
|
AMB_TEMP
|
°C, °F
|
• Ambient air temperature
|
APP
|
%
|
• Displays accelerator pedal opening angle
|
BATT_TERMINAL_CUR_EST
|
A
|
• Displays the estimated current input to integrated starter generator (ISG) terminal 2A.
|
BATT_TERMINAL_VOLT
|
V
|
• Displays the voltage input to integrated starter generator (ISG) terminal 2A.
|
BATT_TERMINAL_VOLT_A/D
|
V
|
• Displays the terminal 2A voltage supplied to the input voltage converter in the integrated starter generator (ISG).
|
BATT_TERMINAL_VOLT_GD
|
V
|
• Displays the terminal 2A voltage supplied to the drive circuit in the integrated starter generator (ISG).
|
BATT_TERMINAL_VOLT_REQ
|
V
|
• Displays the target value of the terminal 2A voltage input from the PCM.
|
B-ISG_RPM
|
r/min
|
• Displays the rotor rotation speed.
|
BRK_SW
|
—
|
• Displays the brake pedal depression status.
|
CTRL_MODE
|
Standby / Torque Control / Voltage Control / System Waiting / System Stopping / System Wakeup / Braking
|
• Displays the control status of the integrated starter generator (ISG).
|
CTRL_MODE_REQ
|
Standby / Torque Control / Voltage Control / System Waiting / System Stopping / System Wakeup / Braking
|
• Displays the control request signal of the integrated starter generator (ISG) input from the PCM.
|
CTRL_TEMP
|
°C, °F
|
• Displays the temperature detected by the control board temperature sensor in the integrated starter generator (ISG).
|
CTRL_TEMP_A/D
|
V
|
• Displays the voltage conversion value for the control board temperature sensor temperature in the integrated starter generator (ISG) supplied to the input voltage converter in the integrated starter generator (ISG).
|
ECT
|
°C, °F
|
• Engine coolant temperature input from ECT sensor No.1
|
ENG_RPM
|
rpm
|
• Displays engine speed
|
ENG_RUN_TIME
|
Second
|
• Time from engine start
|
FIELD_COIL_TEMP_EST
|
—
|
• Displays the field coil temperature (estimated) of the integrated starter generator (ISG).
|
FIELD_CUR
|
A
|
• Displays the field coil current of the integrated starter generator (ISG).
|
FIELD_CUR_A/D
|
V
|
• Displays the field coil current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
FIELD_CUR_OFFSET_A/D
|
V
|
• Displays the measurement difference error value of the field coil current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
FIELD_DUTY
|
%
|
• Displays the field coil control duty value.
|
GLOBAL_REAL_TIME
|
min
|
• Displays the cumulative, total elapsed time since the vehicle was shipped.
|
IG_CYCLE_COUNT
|
times
|
• Displays the number of times power is supplied from the IG1 relay.
|
IG_ON_TIMER
|
min
|
• Displays the elapsed time since the ignition was switched ON (engine off).
|
IG_SIG
|
—
|
SKYACTIV-G
• Displays the power supply status from the electric variable valve timing relay.
SKYACTIV-X
• Displays the power supply status from the exhaust electrical variable valve timing relay.
|
IG_SIG_CAN
|
—
|
• Displays the power supply status from the IG1 relay input via CAN communication.
|
MOSFET_TEMP
|
°C, °F
|
• Displays the 6-phase FET temperature in the integrated starter generator (ISG).
|
MPU_TEMP
|
°C, °F
|
• Displays the microcomputer temperature in the integrated starter generator (ISG).
|
POWER_MODE
|
OFF/ACC/ON/CRANK
|
• Displays the vehicle status.
|
SHIFT_POS
|
Parking/
Reverse/
Neutral/
between 2 position/
Forward Drive 1/
Forward Drive 2/
Forward Drive 3/
Forward Drive 4/
Forward Drive 5/
Forward Drive 6/
Forward Drive 7/
Parking/Neutral/
Invalid
|
• Displays selector lever position
|
TOTAL_DIST
|
km, ft, mi
|
• Total distance
|
TRQ_EST
|
N·m
|
• Displays the output torque request value of the integrated starter generator (ISG).
|
TRQ_RATE_LIM_DECREASE
|
N·m/s
|
• Displays the speed at which the power generation torque decreases.
|
TRQ_RATE_LIM_INCREASE
|
N·m/s
|
• Displays the speed at which the power generation torque increases.
|
TRQ_REQ
|
N·m
|
• Displays the output torque request value input from the PCM.
|
U_PHASE_CUR_A/D
|
V
|
• Displays the value of the U-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
U_PHASE_TEMP_A/D
|
V
|
• Displays the voltage of the U-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
UNDER_VOLT_REQ
|
—
|
• Displays the terminal 2A low voltage error signal of the integrated starter generator (ISG) input via CAN communication.
|
V_PHASE_CUR_A/D
|
V
|
• Displays the value of the V-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
V_PHASE_TEMP_A/D
|
V
|
• Displays the voltage of the V-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
VPWR
|
V
|
• Displays the integrated starter generator (ISG) power supply voltage.
|
VPWR_CBCM
|
V
|
• Body control module (BCM) power supply voltage.
|
VSS
|
KPH, MPH
|
• Displays vehicle speed
|
W_PHASE_CUR_A/D
|
V
|
• Displays the value of the W-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
W_PHASE_TEMP_A/D
|
V
|
• Displays the voltage of the W-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
X_PHASE_CUR_A/D
|
V
|
• Displays the value of the X-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
X_PHASE_TEMP_A/D
|
V
|
• Displays the voltage of the X-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
Y_PHASE_CUR_A/D
|
V
|
• Displays the value of the Y-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
Y_PHASE_TEMP_A/D
|
V
|
• Displays the voltage of the Y-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
Z_PHASE_CUR_A/D
|
V
|
• Displays the value of the Z-phase current converted to voltage which is supplied to the input voltage converter in the integrated starter generator (ISG).
|
Z_PHASE_TEMP_A/D
|
V
|
• Displays the voltage of the Z-phase FET temperature which is supplied to the input voltage converter in the integrated starter generator (ISG).
|