PID/DATA MONITOR TABLE [DC-DC CONVERTER (Mazda M Hybrid)]

PID/DATA MONITOR TABLE [DC-DC CONVERTER (Mazda M Hybrid)]


id140206100100

—: Not applicable

PID/data monitor item

Unit/Operation

Data contents

Module control terminal

A1_CUR
A
•  Displays the current sensor No.1 current set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
A1_TEMP
°C, °F
•  Displays the temperature sensor No.1 temperature set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
A2_CUR
A
•  Displays the current sensor No.2 current set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
A2_TEMP
°C, °F
•  Displays the temperature sensor No.2 temperature set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
B1_CUR
A
•  Displays the current sensor No.1 current set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
B1_TEMP
°C, °F
•  Displays the temperature sensor No.1 temperature set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
B2_CUR
A
•  Displays the current sensor No.2 current set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
B2_TEMP
°C, °F
•  Displays the temperature sensor No.2 temperature set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
BATT_OUT_U
V
•  Displays the output voltage (terminal 3A) of the DC-DC converter (Mazda M Hybrid).
3A
BATT_VOLT
V
•  Displays the supply voltage (terminal 1A) to the microcomputer in the DC-DC converter (Mazda M Hybrid).
1A
CHARGE_WRNG_REQ
•  Displays the illumination request signal of the charging system warning light/indication request signal of the charging system warning indication.
CTRL_STAT_REQ
•  Displays the presence/non-presence of the step-down circuit operation command signal from the PCM.
DCDC_IN_U
V
•  Displays the voltage (terminal 2A) input to the DC-DC converter (Mazda M Hybrid).
2A
DCDC_OUT_CUR_LIM
•  Displays the output current restricted by the DC-DC converter (Mazda M Hybrid).
DCDC_OUT_I
A
•  Displays the current (terminal 3A) output from the DC-DC converter (Mazda M Hybrid).
3A
DCDC_OUT_U
V
•  Displays the target value of the output voltage relative to the DC-DC converter (Mazda M Hybrid) from the PCM.
DCDC_STAT
Ready / Idle / Power Output(Normal) / Power Output(Limit) / Safe Mode / Stop / Error / Initializing / Standby / Power Output(Single-Fail Limit) / Default / Shutdown / Pending Error
•  Displays the operation condition of the DC-DC converter (Mazda M Hybrid).
―  Ready: Step-down preparation completed
―  Idle: Step-down output stopped
―  Power Output (Normal): During output
―  Power Output (Limit): During output (restriction status)
―  Safe Mode: Step-down output stopped (input/output safety switch open status)
―  Stop:Output from the voltage reduction circuit stops due to a temporary voltage reduction circuit malfunction.
―  Error: During Step-down circuit malfunction
―  Initializing: During initializing
―  Standby: On operation standby
―  Power Output (Single-Fail Limit): Single circuit in step-down circuit malfunctioning
―  Default: Fail-safe mode (command error from PCM)
―  Shutdown: During interrupt processing after ignition is switched OFF
―  Pending Error: Availability verification status for restoring from error
DCDC_TEMP
°C, °F
•  Displays the temperature in the DC-DC converter (Mazda M Hybrid).
DEGEN_COUNTER_BATT
•  Displays the number of times the DC-DC converter (Mazda M Hybrid) degenerates with the battery connected.
DEGEN_STOP_COUNTER
•  Displays the number of times the DC-DC converter (Mazda M Hybrid) degeneration was stopped with the battery connected.
DEGEN_WRNG
OK / Degeneracy warning / Degeneracy / Degeneracy Stop
•  Displays the control status in the DC-DC converter (Mazda M Hybrid).
―  OK: Internal DC-DC converter (Mazda M Hybrid) is normal
―  Degeneracy warning: Degeneration concern in DC-DC converter (Mazda M Hybrid)
―  Degeneracy: Degeneration status in DC-DC converter (Mazda M Hybrid)
―  Degeneracy Stop: DC-DC converter (Mazda M Hybrid) function is stopped due to abnormal temperature condition in DC-DC converter (Mazda M Hybrid)
DEGEN_WRNG_COUNTER
•  Displays the number of times the DC-DC converter (Mazda M Hybrid) degeneration was inhibited with the Mazda M Hybrid battery connected.
FORCE_TERMINATE_REQ
•  Displays the presence/non-presence of the step-down circuit forced stop request signal from the PCM.
IG_ON_NUM
•  The number of times the ignition was switched ON with the DC-DC converter (Mazda M Hybrid) installed.
IG_STAT
•  Displays the power supply status from the IG1 relay.
1B
ODR_STORE_REQ
•  Displays the presence/non-presence of the data storage request signal to the PCM.
OUT_CUR_LIM_STAT
•  Displays the current restriction status.
OUT_LIM_REQ
20A / 40A / 60A / 80A / 90A / 95A / 110A / 120A
•  Displays the restricted current.
REGEN_BRK_WRNG
•  Displays the presence/non-presence of the master warning light illumination request signal.
SAFETY_SW_IN_STAT
SW_A(In) Open & SW_B(In) Open/
SW_A(In) Close & SW_B(In) Open/
SW_A(In) Open & SW_B(In) Close/
SW_A(In) Close & SW_B(In) Close
•  Displays the operation status of the safety switch (input side) set in the DC-DC converter (Mazda M Hybrid).
―  SW_A(In) Open & SW_B(In) Open: Safety switch A open and safety switch B open
―  SW_A(In) Close & SW_B(In) Open: Safety switch A closed and safety switch B open
―  SW_A(In) Open & SW_B(In) Close: Safety switch A open and safety switch B closed
―  SW_A(In) Close & SW_B(In) Close: Safety switch A closed and safety switch B closed
SAFETY_SW_OUT_STAT
SW_A(Out) Open & SW_B(Out) Open/
SW_A(Out) Close & SW_B(Out) Open/
SW_A(Out) Open & SW_B(Out) Close/
SW_A(Out) Close & SW_B(Out) Close
•  Displays the operation status of the safety switch (output side) set in the DC-DC converter (Mazda M Hybrid).
―  SW_A(Out) Open & SW_B(Out) Open: Safety switch A open and safety switch B open
―  SW_A(Out) Close & SW_B(Out) Open: Safety switch A closed and safety switch B open
―  SW_A(Out) Open & SW_B(Out) Close: Safety switch A open and safety switch B closed
―  SW_A(Out) Close & SW_B(Out) Close: Safety switch A closed and safety switch B closed
SAFETY_SW_REQ
•  Displays the presence/non-presence of the safety switch open/close request signal of the DC-DC converter (Mazda M Hybrid) from the PCM.
TOTAL_RUN_TIME
min
•  Displays the total operation time of the DC-DC converter (Mazda M Hybrid) since it was assembled to the vehicle.
VPWR
V
•  Displays the supply voltage to the DC-DC converter (Mazda M Hybrid) microcomputer.
1A
WRNG_DISP_REQ
•  Displays the degeneration status of the DC-DC converter (Mazda M Hybrid).