PID/DATA MONITOR TABLE [DC-DC CONVERTER (Mazda M Hybrid)]
id140206100100
PID/data monitor item |
Unit/Operation |
Data contents |
Module control terminal |
---|---|---|---|
A1_CUR
|
A
|
• Displays the current sensor No.1 current set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
|
—
|
A1_TEMP
|
°C, °F
|
• Displays the temperature sensor No.1 temperature set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
|
—
|
A2_CUR
|
A
|
• Displays the current sensor No.2 current set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
|
—
|
A2_TEMP
|
°C, °F
|
• Displays the temperature sensor No.2 temperature set in step-down circuit No.1 in the DC-DC converter (Mazda M Hybrid).
|
—
|
B1_CUR
|
A
|
• Displays the current sensor No.1 current set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
|
—
|
B1_TEMP
|
°C, °F
|
• Displays the temperature sensor No.1 temperature set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
|
—
|
B2_CUR
|
A
|
• Displays the current sensor No.2 current set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
|
—
|
B2_TEMP
|
°C, °F
|
• Displays the temperature sensor No.2 temperature set in step-down circuit No.2 in the DC-DC converter (Mazda M Hybrid).
|
—
|
BATT_OUT_U
|
V
|
• Displays the output voltage (terminal 3A) of the DC-DC converter (Mazda M Hybrid).
|
3A
|
BATT_VOLT
|
V
|
• Displays the supply voltage (terminal 1A) to the microcomputer in the DC-DC converter (Mazda M Hybrid).
|
1A
|
CHARGE_WRNG_REQ
|
—
|
• Displays the illumination request signal of the charging system warning light/indication request signal of the charging system warning indication.
|
—
|
CTRL_STAT_REQ
|
—
|
• Displays the presence/non-presence of the step-down circuit operation command signal from the PCM.
|
—
|
DCDC_IN_U
|
V
|
• Displays the voltage (terminal 2A) input to the DC-DC converter (Mazda M Hybrid).
|
2A
|
DCDC_OUT_CUR_LIM
|
—
|
• Displays the output current restricted by the DC-DC converter (Mazda M Hybrid).
|
—
|
DCDC_OUT_I
|
A
|
• Displays the current (terminal 3A) output from the DC-DC converter (Mazda M Hybrid).
|
3A
|
DCDC_OUT_U
|
V
|
• Displays the target value of the output voltage relative to the DC-DC converter (Mazda M Hybrid) from the PCM.
|
—
|
DCDC_STAT
|
Ready / Idle / Power Output(Normal) / Power Output(Limit) / Safe Mode / Stop / Error / Initializing / Standby / Power Output(Single-Fail Limit) / Default / Shutdown / Pending Error
|
• Displays the operation condition of the DC-DC converter (Mazda M Hybrid).
|
—
|
DCDC_TEMP
|
°C, °F
|
• Displays the temperature in the DC-DC converter (Mazda M Hybrid).
|
—
|
DEGEN_COUNTER_BATT
|
—
|
• Displays the number of times the DC-DC converter (Mazda M Hybrid) degenerates with the battery connected.
|
—
|
DEGEN_STOP_COUNTER
|
—
|
• Displays the number of times the DC-DC converter (Mazda M Hybrid) degeneration was stopped with the battery connected.
|
—
|
DEGEN_WRNG
|
OK / Degeneracy warning / Degeneracy / Degeneracy Stop
|
• Displays the control status in the DC-DC converter (Mazda M Hybrid).
|
—
|
DEGEN_WRNG_COUNTER
|
—
|
• Displays the number of times the DC-DC converter (Mazda M Hybrid) degeneration was inhibited with the Mazda M Hybrid battery connected.
|
—
|
FORCE_TERMINATE_REQ
|
—
|
• Displays the presence/non-presence of the step-down circuit forced stop request signal from the PCM.
|
—
|
IG_ON_NUM
|
—
|
• The number of times the ignition was switched ON with the DC-DC converter (Mazda M Hybrid) installed.
|
—
|
IG_STAT
|
—
|
• Displays the power supply status from the IG1 relay.
|
1B
|
ODR_STORE_REQ
|
—
|
• Displays the presence/non-presence of the data storage request signal to the PCM.
|
—
|
OUT_CUR_LIM_STAT
|
—
|
• Displays the current restriction status.
|
—
|
OUT_LIM_REQ
|
20A / 40A / 60A / 80A / 90A / 95A / 110A / 120A
|
• Displays the restricted current.
|
—
|
REGEN_BRK_WRNG
|
—
|
• Displays the presence/non-presence of the master warning light illumination request signal.
|
—
|
SAFETY_SW_IN_STAT
|
SW_A(In) Open & SW_B(In) Open/
SW_A(In) Close & SW_B(In) Open/
SW_A(In) Open & SW_B(In) Close/
SW_A(In) Close & SW_B(In) Close
|
• Displays the operation status of the safety switch (input side) set in the DC-DC converter (Mazda M Hybrid).
|
—
|
SAFETY_SW_OUT_STAT
|
SW_A(Out) Open & SW_B(Out) Open/
SW_A(Out) Close & SW_B(Out) Open/
SW_A(Out) Open & SW_B(Out) Close/
SW_A(Out) Close & SW_B(Out) Close
|
• Displays the operation status of the safety switch (output side) set in the DC-DC converter (Mazda M Hybrid).
|
—
|
SAFETY_SW_REQ
|
—
|
• Displays the presence/non-presence of the safety switch open/close request signal of the DC-DC converter (Mazda M Hybrid) from the PCM.
|
—
|
TOTAL_RUN_TIME
|
min
|
• Displays the total operation time of the DC-DC converter (Mazda M Hybrid) since it was assembled to the vehicle.
|
—
|
VPWR
|
V
|
• Displays the supply voltage to the DC-DC converter (Mazda M Hybrid) microcomputer.
|
1A
|
WRNG_DISP_REQ
|
—
|
• Displays the degeneration status of the DC-DC converter (Mazda M Hybrid).
|
—
|