DTC U0100:00 [DC-DC CONVERTER (Mazda M Hybrid)]
id140206301900
Outline
System malfunction location |
Communication error with PCM |
---|---|
Detection condition
|
• The DC-DC converter (Mazda M Hybrid) cannot receive CAN signal from the PCM for 1 s or more.
Precondition
• 1.5 s have elapsed after the ignition was switched ON (engine off or on)
• Voltage at DC-DC converter (Mazda M Hybrid) terminal 1A is 9-16 V for a continuous 1 s
|
Fail-safe
|
• The integrated starter generator (ISG) only generates power required for power supply to the 12 V system.
• Inhibits the i-stop control.
• Inhibits the non-power generation control.
• Inhibits regenerative braking by the integrated starter generator (ISG).
• Inhibits motor assist control by the integrated starter generator (ISG).
|
Possible cause
|
• DC-DC converter (Mazda M Hybrid) connector or terminals malfunction
• Short to ground in DC-DC converter (Mazda M Hybrid) CAN_H communication line
• Short to power supply in DC-DC converter (Mazda M Hybrid) CAN_L communication line
• Open circuit in any of the following DC-DC converter (Mazda M Hybrid) circuits.
• Malfunction in CAN communication line between PCM and DC-DC converter (Mazda M Hybrid)
• PCM malfunction
• DC-DC converter (Mazda M Hybrid) malfunction
|
System wiring diagram
|
• Not applicable
|
Connector diagram
|
• Not applicable
|
Diagnostic Procedure