 GENERATOR INSPECTION [MZR-CD (RF Turbo)]

GENERATOR INSPECTION [MZR-CD (RF Turbo)]


id0117f1800300

Generator Warning Light

1. Verify that the battery is fully charged.

• Charge if necessary.

2. Verify that the drive belt deflection/tension is within the specification. (See DRIVE BELT INSPECTION [MZR-CD (RF Turbo)].)

3. Turn the engine switch on and verify that the generator warning light illuminates.

• If not as specified, inspect the generator warning light, and wiring harnesses between the battery and the generator warning light.

4. Verify that the generator warning light goes out after the engine is started.

• If not as specified, inspect the generator.

Generator

Voltage

1. Verify that the battery is fully charged.

• Charge if necessary.

2. Verify that the drive belt deflection/tension is within the specification. (See DRIVE BELT INSPECTION [MZR-CD (RF Turbo)].)

3. Turn off all electrical loads.

4. Turn the engine switch to start the engine and verify that the generator rotates smoothly without any noise while the engine is running.

5. Measure the voltage at each terminal using a tester.

• If not as specified, repair or replace the generator if necessary.
Generator standard voltage [IG-ON]
Terminal B: B+
Terminal P: Approx. 1 V
Terminal D: Approx. 0 V
Generator standard voltage [Idle, 20 °C {68 °F}]
Terminal B: 13-15 V
Terminal P: Approx. 3-8 V
Terminal D: Turn the electrical loads (headlights, blower motor, rear window defroster) on and verify that the voltage reading increases.

Current

Note
• Since the charging current decreases rapidly after starting the engine, perform the following procedure quickly, and read the maximum current value.

1. Verify that the battery is fully charged.

• Charge if necessary.

2. Verify that the drive belt deflection/tension is within the specification. (See DRIVE BELT INSPECTION [MZR-CD (RF Turbo)].)

3. Disconnect the negative battery cable.

4. Connect a tester, which can read 120 A or more, between generator terminal B and the wiring harness.

5. Turn off all electrical loads.

6. Start the engine and increase the engine speed to 2,000-2,500 rpm.

7. Turn the following electrical loads on and verify that the current reading increases.

(1) Headlights
(2) Blower motor
(3) Rear window defroster
• If generator terminal B current does not increase, repair or replace the generator if necessary.
Note
• Current required for generating power varies with the electrical loads applied.

Generator generated current (reference value) [Conditions] Ambient temperature: 20 °C {68 °F}, Voltage: 13.5 V, Engine hot

Engine speed (rpm)

Terminal B current (Lower limit of current must be more than 0 A.)

1,000
0-80 A
2,000
0-90 A

Generator Inner Parts

Rotor

1. Measure the resistance between the slip rings using a tester.

• If not as specified, replace the rotor.
Generator rotor resistance (between slip rings) [20 °C {68 °F}]
1.7-2.1 ohms

2. Verify that there is no continuity between the slip ring and core using a tester.

• If there is continuity, replace the rotor.

3. Inspect the slip ring surface condition.

• If the slip ring surface is rough, use a lathe or fine sandpaper to repair it.

Stator coil

1. Inspect for continuity between the stator coil leads using a tester.

• If there is no continuity, replace the stator.

2. Verify that there is no continuity between the stator coil leads and the core using a tester.

• If there is continuity, replace the stator coil.

Brush

1. Inspect brushes for wear.

• If any brush is worn almost to or beyond the limit, replace all of the brushes.
Generator brush length
Standard: 18.5 mm {0.73 in}
Minimum: 5.0 mm {0.2 in}

Brush spring

1. Measure the force of the brush spring using a spring pressure gauge.

2. Read the spring pressure gauge at the brush tip projection of 2 mm {0.079 in}.

• Replace the brush spring if necessary.
Generator brush spring force
Standard: 4.8-6.0 N {0.49-0.61 kgf, 1.08-1.34 lbf}
Minimum: 2.16 N {0.22 kgf, 0.49 lbf}

Rectifier

1. Inspect for continuity of the diodes using a tester.

• If not as specified, replace the rectifier.

Specification

Tester

Continuity

Negative

Positive

E
P1, P2, P3
Yes
B
No
P1, P2, P3
E
No
B
Yes

Bearing

1. Inspect for abnormal noise, looseness, and sticking.

• Replace the bearing if necessary.