INTAKE AIR TEMPERATURE (IAT) SENSOR INSPECTION [MZR-CD (RF Turbo)]
INTAKE AIR TEMPERATURE (IAT) SENSOR INSPECTION [MZR-CD (RF Turbo)]
id0140f1802200
Resistance Inspection
1. Disconnect the MAF/IAT sensor connector.
2. Measure the resistance between MAF/IAT sensor terminals D and E using an ohmmeter.
-
• If not as specified, replace the MAF/IAT sensor. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)])
-
• If MAF/IAT sensor is okay, perform the "Circuit Open/Short Inspection".
Specification
Ambient temperature
(°C {°F})
|
Resistance (kilohm)
|
20 {68}
|
2.21-2.69
|
Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION [MZR-CD (RF Turbo)])
2. Inspect for open/short circuit in the following wiring harnesses.
-
• If there is open/short circuit, repair or replace wiring harnesses.

Open circuit
-
• MAF/IAT sensor terminal D and PCM terminal 55
-
• MAF/IAT sensor terminal E and PCM terminal 78
Short circuit
-
• MAF/IAT sensor terminal D and power supply
-
• MAF/IAT sensor terminal D and body ground
-
• MAF/IAT sensor terminal E and power supply