1. Inspect the speedometer by setting it in the input/output check mode DTC 12.
1. Adjust the tire air pressure to the specification.
2. Using a speedometer tester, verify that the speedometer indication is within the allowable ranges shown below.
Speedometer tester indication (km/h)
|
Allowable range (km/h)
|
---|---|
20
|
20-24
|
40
|
40-44
|
60
|
60-64
|
80
|
80-85
|
100
|
100-105
|
120
|
120-126
|
140
|
140-146
|
Speedometer tester indication (mph)
|
Allowable range (mph)
|
---|---|
10
|
10-12
|
20
|
20-22
|
30
|
30-32
|
40
|
40-43
|
50
|
50-53
|
60
|
60-63
|
70
|
70-73
|
80
|
80-84
|
3. Verify that fluctuation of the speedometer needle is within the allowable range.
1. Inspect the tachometer by setting it in the input/output check mode DTC 13.
1. Connect the SSTs (WDS or equivalent) to the vehicle DLC-2 16-pin connector.
2. Access and monitor PIDs by SSTs (WDS or equivalent).
1. Inspect the fuel gauge by setting it in the input/output check mode DTC 23.
1. Inspect the water temperature gauge by setting it in the input/output check mode DTC 25.