FAN CONTROL MODULE INSPECTION [SKYACTIV-D 1.8]
id0112t1801100
1. Connect the M-MDS to the DLC-2.
2. Start and warm up the engine.
3. Monitor the engine coolant temperature with the M-MDS.
4. Gradually increase the FAN value from 0 to the maximum possible M-MDS operation value using the simulation function. (See SIMULATION INSPECTION.)(See SIMULATION TABLE [PCM (SKYACTIV-D)].)
5. Using the M-MDS, change the operation condition of the engine coolant temperature under the following conditions, and verify that the cooling fan operates correctly.
Engine coolant temperature °C {°F} |
Cooling fan operation status |
---|---|
less than 98 {208}
|
0%
|
100—108 {212—226}
|
15%
|
more than 108 {226}
|
86%
|
6. If normal operation cannot be verified in Steps 4 and 5, inspect the input signals of the following parts. Replace the cooling fan motor if all the following parts are normal.