DTC U3000:49 [360°VIEW MONITOR CONTROL MODULE]
id1502c7063400
Outline
System malfunction location |
360°view monitor control module internal malfunction |
||||
---|---|---|---|---|---|
Detection condition
|
• The 360°view monitor control module detects a internal malfunction for 5 s.
|
||||
Fail-safe
|
|||||
Possible cause
|
• 360°view monitor control module malfunction
|
||||
System wiring diagram
|
Not applicable
|
||||
Connector diagram
|
Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Results |
Action |
---|---|---|---|
1
|
INSPECT 360°VIEW MONITOR CONTROL MODULE FOR MALFUNCTION
• Clear the DTC recorded in the memory.
(See CLEARING DTC.)
• Perform the DTC inspection for the 360°view monitor control module.
(See DTC INSPECTION.)
• Is the same Pending DTC present?
|
Yes
|
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, replace the 360°view monitor control module and perform the repair completion verification.
|
No
|
Go to the next step.
|
||
Repair completion verification
|
VERIFY IF OTHER DTC IS DISPLAYED
• Perform the DTC inspection.
(See DTC INSPECTION.)
• Are any other DTCs displayed?
|
Yes
|
Repair the malfunctioning location according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|