1. Remove the air hose. (See INTAKE AIR SYSTEM REMOVAL/INSTALLATION [L3 Turbo].)
2. Disconnect the vacuum hose from the variable swirl control solenoid valve.
3. Connect a vacuum pump to the variable swirl shutter valve actuator.
4. Apply vacuum and verify that the rod moves.
Vacuum
kPa {mmHg, inHg}
|
Rod movement
|
---|---|
-2.7 {-20, -0.7} or less
|
Not move
|
-33.4 {-250, -9.9} or more
|
Fully pulled
|