Home

Mazdamanuals.com

GPF PRESSURE SENSOR REMOVAL/INSTALLATION [SKYACTIV-X 2.0]

GPF PRESSURE SENSOR REMOVAL/INSTALLATION [SKYACTIV-X 2.0]


 id0140hf624900

Replacement part

Vacuum hose
 
Quantity: 2
 
Location of use: GPF pressure sensor

1.  Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(E)].)

2.  Remove the engine cover. (See ENGINE COVER REMOVAL/INSTALLATION [SKYACTIV-X 2.0].)

3.  Remove the left wall (rear). (See SIDE WALL REMOVAL/INSTALLATION [SKYACTIV-X 2.0].)

4.  Remove the rear wall. (See SIDE WALL REMOVAL/INSTALLATION [SKYACTIV-X 2.0].)

5.  Disconnect the wiring harness clip of the HO2S. (See HEATED OXYGEN SENSOR (HO2S) REMOVAL/INSTALLATION [SKYACTIV-X 2.0].)

6.  Disconnect the connector shown in the figure.

am3zzw00035762

7.  Remove the bolts shown in the figure.

8.  Remove the GPF pressure sensor.

am3zzw00035763

9.  Install in the reverse order of removal.