DSC RELATED PARTS SENSOR INITIALIZATION PROCEDURE [(E)]
id0415008702x2
Replacement part |
Initialization items |
|||
---|---|---|---|---|
Calibrating Pressure Sensor for DSC |
Calibrating Lateral G Sensor for DSC |
Calibrating Yaw Rate for DSC |
Calibrating Longitudinal G Sensor for DSC |
|
DSC HU/CM or electronically controlled brake unit
|
Implement
|
Implement
|
Implement
|
Implement
|
SAS control module
|
—
|
Implement
|
Implement
|
Implement
|
1. Inspect the wheel alignment and the tire pressure. (See FRONT WHEEL ALIGNMENT [(E)].) (See REAR WHEEL ALIGNMENT [(E)].) (See WHEEL AND TIRE SPECIFICATION [(E)].)
2. Position the vehicle on level ground.
3. Connect the M-MDS to DLC-2.
4. After the vehicle is identified, select the following items from the screen of the M-MDS.
5. Perform the procedure according to the directions on the screen.
6. Drive the vehicle.
7. After 5 min or more of driving, verify that the DSC system is normal.