Home

Mazdamanuals.com

SWIRL CONTROL VALVE POSITION SENSOR INSPECTION [SKYACTIV-X 2.0]

SWIRL CONTROL VALVE POSITION SENSOR INSPECTION [SKYACTIV-X 2.0]


 id0140hf836800

Note
•  The swirl control valve position sensor cannot be removed as a single unit. When replacing the swirl control valve position sensor, replace it together with the intake manifold as a single unit.

PID/DATA Monitor Inspection

1.  Connect the M-MDS to the DLC-2.

2.  Switch the ignition ON (engine off).

3.  Display PID IMRC_ACT and simulation item IMRC_COMD using the M-MDS. (See PID/DATA MONITOR INSPECTION.)(See PID/DATA MONITOR TABLE [PCM (SKYACTIV-X)].)(See SIMULATION INSPECTION.)(See SIMULATION TABLE [PCM (SKYACTIV-X)].)

4.  Verify that the PID IMRC_ACT value conforms to the simulation item IMRC_COMD value when the swirl control valve opening angle simulation item IMRC_COMD is driven using the simulation function.

•  If they cannot be verified, replace the intake manifold. (See INTAKE MANIFOLD REMOVAL/INSTALLATION [SKYACTIV-X 2.0].)