LP-EGR CONTROL VALVE POSITION SENSOR INSPECTION [SKYACTIV-D 1.8]
id0140s1497700
Voltage Inspection
1. Switch the ignition ON (engine off).
2. Connect the M-MDS to the DLC-2.
3. Access the PID/DATA monitor item LO_PRES_EGR_VLV_ACT and simulation item LO_PRES_EGR_VLV_DSD using the M-MDS. (See PID/DATA MONITOR INSPECTION.)(See PID/DATA MONITOR TABLE [PCM (SKYACTIV-D)].)(See SIMULATION INSPECTION.)(See SIMULATION TABLE [PCM (SKYACTIV-D)].)
4. Verify that the LO_PRES_EGR_VLV_ACT monitor value conforms to the LO_PRES_EGR_VLV_DSD monitor value when the simulation item LO_PRES_EGR_VLV_DSD is set from 0 % to 80 %.
Specification (Reference)
am3zzw00029976
|