DOWN SWITCH INSPECTION [ET6A-EL, ET6AX-EL]
id0517n3600600
Continuity Inspection
1. Disconnect the negative battery terminal.(See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(E)].)
2. Remove the following parts:
3. Disconnect the selector lever component connector.
am3zzw00021700
|
4. Verify that the continuity between selector lever component terminals D and H.
am3zzw00026485
|
Down switch specification
Test condition |
Continuity |
---|---|
Selector lever is in the M position (−) side position.
|
Continuity
|
Selector lever is not in the M position (−) side position.
|
No continuity
|