ACTIVE AIR SHUTTER INSPECTION
id092300000600
1. Connect the M-MDS to the DLC-2.
2. Switch the ignition ON (engine off).
3. Display the PCM PID [AIRSHUT_POS_ACT] and the simulation item [AIRSHUT_POS_COMD] using the M-MDS. (See PID/DATA MONITOR INSPECTION.) (See SIMULATION INSPECTION.) (See PID/DATA MONITOR TABLE [PCM (SKYACTIV-G (E))].) (See PID/DATA MONITOR TABLE [PCM (SKYACTIV-D)].) (See PID/DATA MONITOR TABLE [PCM (SKYACTIV-X)].) (See SIMULATION TABLE [PCM (SKYACTIV-G (E))].) (See SIMULATION TABLE [PCM (SKYACTIV-D)].) (See SIMULATION TABLE [PCM (SKYACTIV-X)].)
4. Verify that the PID [AIRSHUT_POS_ACT] value changes according to the simulation item [AIRSHUT_POS_COMD] value when the simulation item [AIRSHUT_POS_COMD] is driven from 0 degrees to the maximum value.