Home

Mazdamanuals.com

DTC TABLE [INTEGRATED STARTER GENERATOR (ISG)]

DTC TABLE [INTEGRATED STARTER GENERATOR (ISG)]


id140202100000

Note
•  When each warning/indicator light turns on/flashes, a message may be displayed in the multi-information display or the center display.

×: Applicable
—: Not applicable

DTC

System malfunction location

Check engine light

Charging system warning indication/Charging system warning light

Master warning indication

Fail-safe function

Drive cycle

Self test type*1

Memory function

Page

P063B:00
Integrated starter generator (ISG) (internal voltage sensor): Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P063C:00
Integrated starter generator (ISG) (internal voltage sensor): Low input
ON
ON
OFF
×
1
C, D
×
P063D:00
Integrated starter generator (ISG) (internal voltage sensor): High input
ON
ON
OFF
×
1
C, D
×
P0A1E:00
Integrated starter generator (ISG) (internal microcomputer): Communication error
ON
ON
OFF
×
1
C, D
×
P0A3E:00
Integrated starter generator (ISG) (internal driver circuit): Overheating
ON
ON
OFF
×
1
C, D
×
P0A4C:00
Integrated starter generator (ISG) (Internal rotor rotation angle sensor): Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P0A4D:00
Integrated starter generator (ISG) (Internal rotor rotation angle sensor): Low input
ON
ON
OFF
×
1
C, D
×
P0A4E:00
Integrated starter generator (ISG) (Internal rotor rotation angle sensor): High input
ON
ON
OFF
×
1
C, D
×
P0A7A:00
Integrated starter generator (ISG) (internal stator coil driver circuit) U-phase, V-phase, W-phase: Malfunction detected
ON
ON
OFF
×
1
C, D
×
P0BCD:00
Integrated starter generator (ISG) (internal FET temperature sensor) U-phase: Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P0BCE:00
Integrated starter generator (ISG) (internal FET temperature sensor) U-phase: Low input
ON
ON
OFF
×
1
C, D
×
P0BCF:00
Integrated starter generator (ISG) (internal FET temperature sensor) U-phase: High input
ON
ON
OFF
×
1
C, D
×
P0DF4:00
Integrated starter generator (ISG) (internal FET temperature sensor) V-phase: Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P0DF5:00
Integrated starter generator (ISG) (internal FET temperature sensor) V-phase: Low input
ON
ON
OFF
×
1
C, D
×
P0DF6:00
Integrated starter generator (ISG) (internal FET temperature sensor) V-phase: High input
ON
ON
OFF
×
1
C, D
×
P0DF7:00
Integrated starter generator (ISG) (internal FET temperature sensor) W-phase: Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P0DF8:00
Integrated starter generator (ISG) (internal FET temperature sensor) W-phase: Low input
ON
ON
OFF
×
1
C, D
×
P0DF9:00
Integrated starter generator (ISG) (internal FET temperature sensor) W-phase: High input
ON
ON
OFF
×
1
C, D
×
P0DFA:00
Integrated starter generator (ISG) (stator coil U-phase, V-phase, or W-phase: Current sensor): Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P0E02:00
Integrated starter generator (ISG) (stator coil U-phase: Current sensor): Low input
ON
ON
OFF
×
1
C, D
×
P0E03:00
Integrated starter generator (ISG) (stator coil U-phase: Current sensor): High input
ON
ON
OFF
×
1
C, D
×
P0E06:00
Integrated starter generator (ISG) (stator coil V-phase: Current sensor): Low input
ON
ON
OFF
×
1
C, D
×
P0E07:00
Integrated starter generator (ISG) (stator coil V-phase: Current sensor): High input
ON
ON
OFF
×
1
C, D
×
P0E0A:00
Integrated starter generator (ISG) (stator coil W-phase: Current sensor): Low input
ON
ON
OFF
×
1
C, D
×
P0E0B:00
Integrated starter generator (ISG) (stator coil W-phase: Current sensor): High input
ON
ON
OFF
×
1
C, D
×
P0E10:00
Integrated starter generator (ISG): Power supply voltage decreases
ON
ON
OFF
×
1
C, D
×
P0E11:00
Integrated starter generator (ISG): Power supply voltage increases
ON
ON
OFF
×
1
C, D
×
P1BC0:00
Integrated starter generator (ISG) (internal microcomputer): Malfunction detection
ON
ON
OFF
×
1
C, D
×
P1BC3:00
Integrated starter generator (ISG) (internal microcomputer): Non-volatile RAM error
ON
OFF
ON
×
1
C, D
×
P1BC5:00
Integrated starter generator (ISG) (internal stator coil driver circuit) X-phase, Y-phase, Z-phase: Malfunction detected
ON
ON
OFF
×
1
C, D
×
P1BC6:00
Integrated starter generator (ISG) (internal field coil drive circuit): Circuit malfunction, function malfunction
ON
ON
OFF
×
1
C, D
×
P1BC9:00
Integrated starter generator (ISG): IG power supply malfunction
ON
OFF
ON
×
1
C, D
×
P1BD0:00
Integrated starter generator (ISG) (internal FET temperature sensor) X-phase: High input
ON
ON
OFF
×
1
C, D
×
P1BD1:00
Integrated starter generator (ISG) (internal FET temperature sensor) X-phase: Low input
ON
ON
OFF
×
1
C, D
×
P1BD2:00
Integrated starter generator (ISG) (internal FET temperature sensor) X-phase: Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P1BD3:00
Integrated starter generator (ISG) (internal FET temperature sensor) Y-phase: High input
ON
ON
OFF
×
1
C, D
×
P1BD4:00
Integrated starter generator (ISG) (internal FET temperature sensor) Y-phase: Low input
ON
ON
OFF
×
1
C, D
×
P1BD5:00
Integrated starter generator (ISG) (internal FET temperature sensor) Y-phase: Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P1BD6:00
Integrated starter generator (ISG) (internal FET temperature sensor) Z-phase: High input
ON
ON
OFF
×
1
C, D
×
P1BD7:00
Integrated starter generator (ISG) (internal FET temperature sensor) Z-phase: Low input
ON
ON
OFF
×
1
C, D
×
P1BD8:00
Integrated starter generator (ISG) (internal FET temperature sensor) Z-phase: Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P1BD9:00
Integrated starter generator (ISG) (internal control board temperature sensor): High input
ON
ON
OFF
×
1
C, D
×
P1BDA:00
Integrated starter generator (ISG) (internal control board temperature sensor): Low input
ON
ON
OFF
×
1
C, D
×
P1BDB:00
Integrated starter generator (ISG) (internal control board temperature sensor): Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P1BE0:00
Integrated starter generator (ISG) (stator coil X-phase: Current sensor): High input
ON
ON
OFF
×
1
C, D
×
P1BE1:00
Integrated starter generator (ISG) (stator coil X-phase: Current sensor): Low input
ON
ON
OFF
×
1
C, D
×
P1BE2:00
Integrated starter generator (ISG) (stator coil Y-phase: Current sensor): High input
ON
ON
OFF
×
1
C, D
×
P1BE3:00
Integrated starter generator (ISG) (stator coil Y-phase: Current sensor): Low input
ON
ON
OFF
×
1
C, D
×
P1BE4:00
Integrated starter generator (ISG) (stator coil Z-phase: Current sensor): High input
ON
ON
OFF
×
1
C, D
×
P1BE5:00
Integrated starter generator (ISG) (stator coil Z-phase: Current sensor): Low input
ON
ON
OFF
×
1
C, D
×
P1BE6:00
Integrated starter generator (ISG) (stator coil X-phase, Y-phase, or Z-phase: Current sensor): Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
P1BE7:00
Integrated starter generator (ISG) (internal field coil current sensor): High input
ON
ON
OFF
×
1
C, D
×
P1BE8:00
Integrated starter generator (ISG) (internal field coil current sensor): Low input
ON
ON
OFF
×
1
C, D
×
P1BE9:00
Integrated starter generator (ISG) (internal field coil current sensor): Sensor characteristic malfunction
ON
ON
OFF
×
1
C, D
×
U0073:00
Module communication error (CAN BUS No.1)
ON
ON
OFF
×
1
C, D
×
U0100:00
Communication error with PCM
ON
ON
OFF
×
1
C, D
×
U0401:00
Error signal received from PCM
ON
ON
OFF
×
1
C, D
×

*1  :C: CMDTC self test, D: ODDTC self test