INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS [FULL-AUTO AIR CONDITIONER]
id0703c1700300
Troubleshooting item |
Insufficient air (or no air) blown from vents |
|
---|---|---|
Description
|
• Insufficient airflow from vent or duct
• No airflow from vent or duct
• Airflow mode does not change
|
|
Possible cause
|
• Air filter clogging
• Blower system malfunction
• Air vent clogging
• Duct malfunction
• A/C unit malfunction
• Evaporator frozen due to evaporator temperature sensor malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
PERFORM DASH-ELECTRICAL SUPPLY UNIT DTC INSPECTION
• Perform the dash-electrical supply unit DTC inspection using the M-MDS.
(See DTC INSPECTION.)
• Are any DTCs displayed?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
Go to the next step.
|
||
2
|
INSPECT AIR FILTER FOR CLOGGING
• Is the air filter clogged?
|
Yes
|
Replace the air filter.
Go to step 10.
|
No
|
Go to the next step.
|
||
3
|
VERIFY BLOWER MOTOR OPERATION
• Switch the ignition ON (engine off or on).
• Set the airflow volume control switch to MAX.
• Does the blower motor rotate?
|
Yes
|
Go to the next step.
|
No
|
Go to the following symptom troubleshooting.
|
||
4
|
VERIFY AIRFLOW CONDITION
• Set the airflow mode to VENT mode.
• Turn the A/C switch off.
• Set the airflow volume control switch to MAX.
• Does sufficient air flow from the vents when the airflow mode is in VENT mode?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 7.
|
||
5
|
VERIFY AIRFLOW CONDITION
• Set the airflow mode to HEAT mode.
• Turn the A/C switch off.
• Set the airflow volume control switch to MAX.
• Does sufficient air flow from the vents when the airflow mode is in HEAT mode?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 7.
|
||
6
|
VERIFY AIRFLOW CONDITION
• Set the airflow mode to DEFROSTER mode.
• Turn the A/C switch off.
• Set the airflow volume control switch to MAX.
• Does sufficient air flow from the vents when the airflow mode is in DEFROSTER mode?
|
Yes
|
Go to Step 9.
|
No
|
Go to the next step.
|
||
7
|
VERIFY DUCT INSTALLATION CONDITION
• Is the duct under any of the following conditions? Clogging Deformation Air leakage Poor installation
(See DASHBOARD REMOVAL [(E)].)
(See DASHBOARD INSTALLATION [(E)].)
|
Yes
|
Go to the next step.
|
No
|
Install the incorrectly installed ducts properly, then go to Step 10.
|
||
8
|
VERIFY AIRFLOW MODE LINK OPERATION
• Remove the airflow mode actuator.
• Verify the operation by manually operating the airflow mode link.
• Does the airflow mode link operate smoothly?
|
Yes
|
Replace the A/C unit because there is a malfunction in the airflow mode door.
Go to Step 10.
|
No
|
Replace the airflow mode link.
Go to Step 10.
|
||
9
|
VERIFY EVAPORATOR TEMPERATURE SENSOR
• Inspect the evaporator temperature sensor.
• Is the evaporator temperature sensor normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the evaporator temperature sensor.
Go to Step 10.
|
||
Repair completion verification
|
VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR
• Is air discharged from vent?
• Does air flow from the vent while in each airflow mode?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.