COOLING SYSTEM CONCERNS-RUNS COLD [SKYACTIV-D]

COOLING SYSTEM CONCERNS-RUNS COLD [SKYACTIV-D]


 id0103s5890500

Troubleshooting item

COOLING SYSTEM CONCERNS-RUNS COLD

Description
•  Engine does not reach normal operating temperature.
Possible cause
•  PCM DTC is stored.
•  Erratic signal to PCM
―  ECT sensor or related circuit malfunction
•  Fan control module malfunction
•  Active air shutter actuator malfunction
•  Cooling system malfunction
―  Active air shutter is fully-opened and does not operate
―  There is foreign matter caught in active air shutter
―  Coolant control valve malfunction
System wiring diagram
•  Not applicable
Connector diagram
•  Not applicable


Diagnostic Procedure

Step

Inspection

Results

Action

1
VERIFY PCM DTC
•  Retrieve PCM DTCs using the M-MDS.
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
2
VERIFY CURRENT INPUT SIGNAL STATUS
Caution
•  While performing this step, always operate the vehicle in a safe and lawful manner.
•  When the M-MDS is used to observe monitor system status while driving, be sure to have another technician with you, or record the data in the M-MDS using the PID/DATA MONITOR AND RECORD capturing function and inspect later.
•  Access the following PID using the M-MDS:
PCM
―  ECT
•  Does the PID indicate the correct value under the trouble condition?
Yes
Inspect the related sensor and circuit.
•  If there is any malfunction:
―  Repair or replace the malfunctioning part according to the inspection results, then go to Step 6.
•  If there is no malfunction:
Vehicles with active air shutter:
―  Go to the next step.
Vehicles without active air shutter:
―  Go to step 5.
No
Vehicles with active air shutter:
•  Go to the next step.
Vehicles without active air shutter:
•  Go to step 5.
3
VERIFY IF MALFUNCTION IS CAUSED BY TRAPPED AIR IN ENGINE OIL SOLENOID VALVE
•  Access the following simulation items using the M-MDS:
―  AIRSHUT_POS_COMD
•  Change to the following conditions using the simulation function.
―  AIRSHUT_POS_COMD: 100 %
•  Access the AIRSHUT_POS_ACT PID using the M-MDS.
•  Verify that the AIRSHUT_POS_ACT monitor value conforms to the AIRSHUT_POS_COMD monitor value when the simulation item AIRSHUT_POS_COMD is set from 0 % to 100 %.
Yes
Go to Step 5.
No
Go to the next step.
4
INSPECT ACTIVE AIR SHUTTER FOR MALFUNCTION
•  Inspect the applicable part.
•  Is the part normal?
Yes
Go to the next step.
No
Repair or replace the malfunctioning location and perform the repair completion verification.
5
INSPECT FAN CONTROL MODULE FOR MALFUNCTION
•  Inspect the applicable part.
•  Is the part normal?
Yes
Go to the next step.
No
Repair or replace the malfunctioning location and perform the repair completion verification.
6
DETERMINE IF MALFUNCTION CAUSE IS COOLANT CONTROL VALVE OR OTHER
•  Verify the radiator hose tension.
Warning
•  To prevent burns, use a cloth with your hand to verify the tension of the radiator hose.
•  After the engine warms up, does the engine coolant circulate to the radiator hose?
Yes
Go to repair completion verification 2.
No
Go to the next step.
7
INSPECT COOLANT CONTROL VALVE FOR MALFUNCTION
•  Inspect the applicable part.
•  Is the part normal?
Yes
Go to the next step.
No
Repair or replace the malfunctioning location and perform the repair completion verification.
Repair completion verification 1
VERIFY THAT VEHICLE IS REPAIRED
•  Install/connect the part removed/disconnected during the troubleshooting procedure.
•  Has the malfunction symptom been eliminated?
Yes
Complete the symptom troubleshooting. (Explain contents of repair to customer)
No
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
•  If the CAN communication is normal, perform the diagnosis from Step 1.
―  If the malfunction recurs, go to the next step.
Repair completion verification 2
VERIFY IF MALFUNCTION IS CAUSED BY NOT PERFORMING PCM REPROGRAMMING
•  Verify repair information and verify that there is a new calibration in the PCM.
•  Is there a new calibration in the PCM?
Yes
Perform the PCM reprogramming and verify if the malfunction symptom was corrected.
•  If the malfunction recurs, replace the PCM.
No
Replace the PCM.